Recalls for your 1987 Dodge W100

Recalls for 1987 Dodge W100

RSS Feed


2 recalls found.
All Dodge Recalls
Sorry, could not fetch this feed! (items)

DEFECT #1 - STRUCTURE:BODY:BUMPERS


Posted on: 1990-07-31
Description
In a rear end collision, the pickup box crossmember could contact the fuel pump modules fuel line, causing a fuel leak which would be in non-compliance with fmvss 301.

Consequence
Consequence of defect: leakage of fuel could cause a fire if a source of ignition is present.

Corrective Action
Install two pickup box reinforcement blocker brackets to the undercarriage to eliminate contact with fuel line.

Notes
System: rear bumper; fuel system; fmvss 301.vehicle description: pickup trucks with 6 1/2 foot boxes, efi, and no rear bumper.

DEFECT #2 - POWER TRAIN:CLUTCH ASSEMBLY


Posted on: 1987-03-30
Description
Plastic hydraulic clutch system components are subject to exhaust system heat damage due to prolonged cold, high speed idle operation.

Consequence
Consequence of defect: hydraulic fluid leakage could occur creating the potential for a minor fire from fluid contacting the hot exhaust.

Corrective Action
Install protective heat shields between the exhaust system and affected clutch system components.

Notes
System: plastic hydraulic clutch components.vehicle description: pickup trucks equipped with 6 cylinder engine and manual transmission.