DEFECT #1 - FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP


Posted on: 1988-05-24
Description
Fuel filler neck could be positioned or installed in a way that allows fuel to enter the passenger compartment under certain conditions.

Consequence
Fuel odor would be present and in presence of an ignitionsource, could result in a fire.

Corrective Action
Remove fuel filler neck and relocate below floorline of bus.

Notes
System: fuel filler neck.vehicle description: 40 ft.  Metroliner buses.

DEFECT #2 - ELECTRICAL SYSTEM:FUSES AND CIRCUIT BREAKERS


Posted on: 1988-05-24
Description
The 25 amp automatic reset circuit breaker could fail in the closed position.

Consequence
This could jeopardize the circuitry to be protected bythe circuit breaker and could result in an electrical fire.

Corrective Action
Replace circuit breaker.

Notes
System: electrical/circuit breaker.vehicle description: 30, 35, 40, and 60 ft.  Transit buses.