Recalls for your 2016 Aev Traumahawk

Recalls for 2016 Aev Traumahawk

RSS Feed


4 recalls found.
All Aev Recalls
Sorry, could not fetch this feed! (items)

DEFECT #1 - EQUIPMENT


Posted on: 2016-12-15
Description
Halcore group, inc.  (halcore) is recalling certain 2016 aev traumahawk ambulances manufactured march 20, 2016, to october 28, 2016.  The affected vehicles are equipped with stryker medical performance cot mounts that may not securely attach the cot into place.

Consequence
If the cot dislodges from its mount, serious injury may occur to the patient and/or to individuals within the ambulance body.

Corrective Action
All affected vehicles have been contacted by stryker, received a remedy kit and the vehicles have been repaired, therefore an owner notification letter will not be issued for this campaign.  Owners may contact aev customer service at 1-800-374-9749.  

Notes
Owners may also contact the national highway traffic safety administration vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to www.safercar.gov.

DEFECT #2 - STRUCTURE:BODY:DOOR:HINGE AND ATTACHMENTS


Posted on: 2017-09-15
Description
Halcore group, inc.  (halcore) is recalling certain 2016-2017 american emergency vehicles (aev) traumahawk type iii ambulances, equipped with door striker bolts that may fail under load.  As such, these bolts fail to comply with the requirements of federal motor vehicle safety standard (fmvss) number 206, door locks and door retention components.

Consequence
If the door striker bolts fail under load, the door may open in a crash, increasing the risk of injury.

Corrective Action
Aev will notify owners, and dealers will replace the striker bolts, free of charge.  The recall began on september 15, 2017.  Owners may contact aev customer service at 1-800-374-9749.  Halcore's number for this recall is 17e-038.

Notes
Owners may also contact the national highway traffic safety administration vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to www.safercar.gov.

DEFECT #3 - ELECTRICAL SYSTEM:BATTERY


Posted on: 2018-02-09
Description
Halcore group, inc.  (halcore) is recalling certain 2017 aev traumahawk ambulances.  These vehicles are equipped with a vanner incorporated-brand battery isolator module which may overheat and cause equipment failure.

Consequence
If the battery isolator module overheats there is an increased risk of a fire.  Additionally, if the equipment that is connected to the isolator does not work there is an increased risk of injury.  

Corrective Action
Halcore will notify owners and dealers will replace the battery isolator module.  The recall is expected to begin on april 9, 2018.  Owners may contact halcore customer service at 1-800-447-0343.

Notes
Owners may also contact the national highway traffic safety administration vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to www.safercar.gov.

DEFECT #4 - BACK OVER PREVENTION: SENSING SYSTEM: CAMERA


Posted on: 2019-04-09
Description
Halcore group, inc.  (halcore) is recalling certain 2016-2019 american emergency vehicles (aev) traumahawk ambulances equipped with asa electronics back-up camera displays.  The affected displays may revert back to the factory default settings which may cause the camera image to be reversed.

Consequence
The driver may inadvertently turn the wrong direction to avoid an object behind the vehicle, increasing the risk of a crash.

Corrective Action
Aev will notify owners and dealers will add a harness relay capacitor module to prevent the image from reversing, free of charge.  The recall began june 11, 2019.  Owners may contact asa customer service at 1-800-384-4400 or halcore at 1-800-447-0343.  

Notes
Owners may also contact the national highway traffic safety administration vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to www.safercar.gov.