1973 Checker A11e Recall Information and Defects

The 1973 Checker A11e has 1 active safety recalls issued by the NHTSA and CHECKER MOTORS CORP.. These critical defects primarily concern vacuum. Review the full details below, including NHTSA and Manufacturer Campaign numbers.

All Checker Recalls
RSS Feed


No image found.

Quick Jump to Recalls (1 Defects)

Recall #1: Vacuum ()

Defect #1: Vacuum Malfunction (MFR Campaign: )

NHTSA ID: 74V030000 | MFR Campaign Number: Posted on: 1979-10-12

Description



Consequence



Corrective Action



Notes

Checker campaign no n/a. Possibility that the single diaphragm brake vacuumpower booster was assembled with dimensional discrepancies in the vacuum powerbooster housing which may reduce the torque required to unlock the front halfof the housing from the rear half. If this condition exists, the low unlockingtorque coupled with other variations in the assembly may cause housing torotate and disengage from the locking tabs resulting in separation of the twohalves of the booster and complete loss of brakes. (correct by inspecting andstaking the housing at two points to preclude rotation of the housing)