DEFECT #1 - ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS

Posted on: 1995-10-11
Description
A solder bridge on the printed circuit board within the fuse panel of the power converter passed undetected through a test fixture and bypasses the fuse protecting the circuit.

Consequence
This solder bridge, when coupled with a dead short else where in the system, can result in circuit overload, overheating, and even fire, without warning.

Corrective Action
Detailed test instructions are being provided.  If a defective fuse panel is found, a new replacement panel will be installed.

Notes
System: electrical; fuse and fuse recepticle. Vehicle description: recreational vehicles equipped with magnetek power converters which use doran manufacturing fuse panels. Note: if the fuse panels are not replaced free of charge within a reasonable time, please contact skyline at 1-219-294-6521. Also contact the national highway traffic safety administration's auto safety hotline at 1-800-424-9393