DEFECT #1 - ELECTRICAL SYSTEM:FUSES AND CIRCUIT BREAKERS
Posted on: 1996-04-18
Description
A solder bridge on the printed circuit board within the fuse panel of the power converter passed undetected through a test fixture and bypasses the fuse protecting the circuit.
Consequence
This solder bridge, when coupled with a dead short else where in the system, can result in circuit overload, overheating, and even fire, without warning.
Corrective Action
Detailed test instructions are being provided. If a defective fuse panel is found, a new replacement panel will be installed.
Notes
System: electrical; fuse and fuse recepticle. Vehicle equipment: transit bus equipped with magnetek power converters which use a doran manufacturing fuse panel. (see doran campaign no. 95e016). Note: if the fuse panels are not replaced free of charge within a reasonable time, please contact doran at 1-800-681-5424. Also contact the national highway traffic safety administration's auto safety hotline at 1-800-424-9393.